(请使用IE浏览器访问本系统)

  学科分类

  基础科学

  工程技术

  生命科学

  人文社会科学

  其他

篇目详细内容

【篇名】 Reduction of hexavalent chromium with scrap iron in a fixed bed reactor
【刊名】 Frontiers of Environmental Science and Engineering
【刊名缩写】 Front.Environ.Sci.Eng.
【ISSN】 2095-2201
【EISSN】 2095-221X
【DOI】 10.1007/s11783-012-0413-z
【出版社】 Higher Education Press and Springer-Verlag Berlin Heidelberg
【出版年】 2012
【卷期】 6 卷6期
【页码】 761-769 页,共 9 页
【作者】 Yin WANG; Xuejiang WANG; Xin WANG; Mian LIU; Siqing XIA; Daqiang YIN; Yalei ZHANG; Jianfu ZHAO;
【关键词】 hexavalent chromium; scrap iron; reduction capacity; drinking water

【摘要】
The reduction of hexavalent chromium by scrap iron was investigated in continuous long-term fixed bed system. The effects of pH, empty bed contact time (EBCT), and initial Cr(VI) concentration on Cr(VI) reduction were studied. The results showed that the pH, EBCT, and initial Cr(VI) concentration significantly affected the reduction capacity of scrap iron. The reduction capacity of scrap iron were 4.56, 1.51, and 0.57?mg Cr(VI)·g?1 Fe0 at pH 3, 5, and 7 (initial Cr(VI) concentration 4?mg·L?1, EBCT 2?min, and temperature 25°C), 0.51, 1.51, and 2.85?mg Cr(VI)·g?1 Fe0 at EBCTs of 0.5, 2.0, and 6.0?min (initial Cr(VI) concentration 4?mg·L?1, pH 5, and temperature 25°C), and 2.99, 1.51, and 1.01?mg Cr(VI)·g?1 Fe0 at influent concentrations of 1, 4, and 8?mg·L?1 (EBCT 2 min, pH 5, and temperature 25°C), respectively. Fe(total) concentration in the column effluent continuously decreased in time, due to a decrease in time of the iron corrosion rate. The fixed bed reactor can be readily used for the treatment of drinking water containing low amounts of Cr(VI) ions, although the hardness and humic acid in water may shorten the lifetime of the reactor, the reduction capacity of scrap iron still achieved 1.98?mg Cr6+·g?1 Fe. Scanning electron microscope equipped with energy dispersion spectrometer and X-ray diffraction were conducted to examine the surface species of the scrap iron before and after its use. In addition to iron oxides and hydroxide species, iron-chromium complex was also observed on the reacted scrap iron.
版权所有 © CALIS管理中心 2008